HomeProductsMachinesBrandsGuidesAboutReviewsSupport

Murray Ignition Coils

Murray Ignition Coils
Ignition coils in this section are for Murray garden machinery, including replacement coils for engines that have lost spark. If your mower fires up from cold then stops once warm before starting again later, the coil is a common cause. On Lawnmower Spares, use your model number or part number to match the correct genuine or OEM Murray part. When fitting, set the coil-to-flywheel gap accurately.

Frequently Asked Questions

Why does it run until it gets hot?
A failing ignition coil can show up as an engine that starts from cold, then cuts out once it warms up. After cooling down, it often restarts again, which is a classic sign to investigate the coil.
How can I check for spark?
Use a known-good spark plug and check whether the engine is producing a spark. If there is no spark during the test, the ignition coil is one of the key parts to look at.
How do I set the coil gap?
When fitting an ignition coil, the air gap between the coil and flywheel needs to be set correctly. A business card is the traditional gauge used to set that gap.